The Honeywell 8C-IP0102 (PN 51454362-275) has become a preferred solution for plants that still depend on PROFIBUS PA transmitters and PROFIBUS DP valve positioners.

 Instead of replacing field wiring during a control-system upgrade, this gateway allows facilities to keep existing PROFIBUS devices while moving the DCS layer to Experion.

The result is lower project cost, shorter downtime, and a smoother migration path.


1. What the 8C-IP0102 Does

The 8C-IP0102 is the Series-8 PROFIBUS gateway designed for Honeywell Experion systems. A single module fits into one IOTA slot on the C300 I/O rail and supports up to 126 DP devices or 64 PA devices, depending on the segment and power couplers used.

The module automatically captures and stores GSD files in non-volatile memory. This means that even after a controller cold start, the network does not need to be re-scanned manually—saving time and avoiding configuration errors.


2. Why It Matters in Modern Plants

Although often labeled “legacy,” PROFIBUS remains widespread. A 2024 ARC study found that 62% of chemical plants still operate PA devices on 31.25 kbit/s bus segments.

The 8C-IP0102 enables users to modernize their control systems to Experion R520 or later without replacing junction boxes, field cables, or installed devices. This also avoids hazardous-area hot-work permits and removes the need to re-calibrate instruments already proven in service.


3. Fast and Predictable Performance

The gateway transfers PROFIBUS data directly into the C300’s peer-to-peer memory. Its update rate is deterministic—32 ms per 1 kB of cyclic I/O—providing stable performance suitable even for loops requiring SIL-rated response times when used with remote I/O.

It also supports DPV1 alarms, enabling asset-management features such as drift alerts, temperature warnings, and plug-in timestamps. Importantly, these diagnostics require no additional licenses.


4. Built-In Cybersecurity Through Architecture

The 8C-IP0102 sits on the secure side of the C300 controller. The module itself has no Ethernet stack, ensuring that only the controller communicates with the network.

This architecture means that technicians can work on the PROFIBUS cabling during maintenance without adding exposure to the plant network or requiring firewall rule changes. The physical layer stays isolated while still delivering continuous data to Experion.


5. Proven Field Results

Real-world projects highlight the cost and time savings delivered by the 8C-IP0102:

North German Refinery:
One gateway connected to 48 PA transmitters on a distillation column. Start-up time was reduced by 3 days, preventing production losses worth €480,000.

Gulf Coast LDPE Facility:
Reused 300 DP drives without recabling. The project avoided 4 km of new wiring and 12 explosion-proof junction boxes, cutting CAPEX by USD 1.1 million.

Brazilian Bio-ETH Plant:
Integrated third-party PA flowmeters in 6 hours, using the gateway’s built-in GSD library—no vendor support required on-site.


6. Availability and Warranty

Amikon maintains stock of the 8C-IP0102 (51454362-275) with firmware version v03.06.
Each module undergoes rack testing on a live C300F controller before shipping and is backed by a 12-month replacement warranty. This ensures customers receive reliable, certified hardware ready for immediate installation.


7. Your Next Step

To secure units before your next shutdown or upgrade window, contact May at Sales5@amikon.cn.
With the 8C-IP0102, you can preserve your PROFIBUS field devices while stepping confidently into the future of Experion automation.